Between November 4 and 7, 2026 we built two things for the Rhino skill and then tested them in the Rhino 9 AI panel. The first is a Rhino command, ASCheck, that measures the open model against requirements stored in the document. The second is a gate hook that blocks, once, a turn that changed the model without a passing check. We tested them on one bathroom model that grew over three scenarios: S1, a standard toilet; S2, the same room as an accessible single-user toilet room; S3, a two-compartment public restroom. We added a control run for S3 and two probe runs (P1 and P2) of the S2 brief. That is seven runs in all, one of them (S2a) off-script and kept as a data point.
In the six runs without hooks, the agent read the whole skill when the brief told it to, wrote requirements before its first model change, and ran the checker after its last change in all 7 of the 7 turns that changed the model. An independent grader agreed with the agent’s own pass in S1, S2 (after we fixed an answer-key defect), S3 and the S3 control. It did not agree in P2: the agent’s check passed 24 of 24 and the key failed 21 of 22, on a toilet paper dispenser that was in neither the requirements nor the model. The same item was missing in S2 before the tester’s correction and in P1. The agent’s check can only cover the requirements the agent wrote.
This is a factual report of runs made over four days. The skill is the /as:rhino skill in our private skills repository; how it got here is in a separate article. Every number below comes from the run records we kept, the test plan and spec, or the planning session’s transcript (rows dated before November 9), except where we say a figure is carried over from a record and was not recomputed.
Results at a glance
All runs are one trial each, in a new panel conversation, on one Mac. “Self-check” is the agent’s own ASCheck result at the end. “Independent” is our answer key run through a separate grader that the agent could not influence. Input tokens include cache reads, as the harvester counts them.
| Run | Date | Setup | Self-check | Independent grader | Tool calls | Input tokens | Output tokens |
|---|---|---|---|---|---|---|---|
| S1 | Nov 4 | Hooks on; standard toilet | 16 of 16, 6 stated | 13 of 14 as written; 16 of 16 after a key fix | 22 | 855,005 | 18,021 |
| S2a | Nov 6 | Hooks off; off-script, not scored as S2 | 34 of 34, 10 stated | not graded | 14 | 986,452 | 36,576 |
| S2 | Nov 6 | Hooks off; accessible toilet room, planted correction | 36 of 36, 11 stated | 21 of 22 as written; 23 of 23 after a key fix (1 review item) | 15 | 1,101,072 | 42,592 |
| S3 | Nov 7 | Hooks off; lessons adopted; public restroom | 56 of 56, 17 stated | 22 of 22, 8 of 8 (1 review), 6 of 6 | 10 | 739,873 | 39,398 |
| S3 control | Nov 7 | Same, lessons not adopted | 54 of 54, 17 stated | 22 of 22, 8 of 8 (1 review), 6 of 6 | 10 | 817,526 | 36,872 |
| P1 | Nov 7 | S2 brief, with the dispenser lesson | 24 of 25, 8 stated | 21 of 22 (3 review) | 9 | 592,304 | 21,218 |
| P2 | Nov 7 | S2 brief, control | 24 of 24, 7 stated | 21 of 22 (4 review) | 14 | 753,674 | 23,357 |
| Total, 7 runs | 94 | 5,845,906 | 218,034 |
Process measures from the harness’s metrics files and transcripts, in the 6 runs without hooks:
| Measure | Result |
|---|---|
Whole SKILL.md read, and before the first model change (M11) | 6 of 6 |
| Requirements written before the first model change (M1) | 6 of 6 (S1, with hooks, also yes, after one denial) |
| Requirements revised before the model was edited, on a changed brief (M7) | 6 of 6 |
Turns that changed the model and ran ASCheck after the last change (M12) | 7 of 7 |
| Gate blocks | 0 in all 7 runs |
| Requirements-first denials | 1 in S1, 0 elsewhere |
| Runs whose final check passed | 6 of 7 (P1 ended with one failed check, accepted by the tester) |
| Corrections from the tester beyond the planted one (M8) | 0 in S1, S2, S3 and the S3 control; not recorded for S2a, P1 and P2 |
We did not record cost in dollars or wall time for the panel runs. The two learning-step sessions we ran cost $1.01 and $1.61 (see “Metrics”).
Inputs
What we were testing
We set three objectives in the test plan, written November 4 before S1:
| Objective | Question |
|---|---|
| O1. Requirements first | Does the agent write requirements from the brief and the templates before building, and are they right? |
| O2. Requirements rebuild themselves | When the brief changes, do the requirements change first, does the check fail on the old model, and does the rebuilt model pass with no stale requirement left? |
| O3. Lessons carry forward | Do failures and corrections from earlier scenarios, once harvested and adopted, show up as fewer repeats and better requirements later? |
Each scenario started a new panel conversation, so the only things carried forward were files: the model with its requirements stored in the document, the templates, the skill. We snapshotted the panel project’s auto-memory folder before each run. All seven snapshots show no files, the plan’s rule was to quarantine any file that appeared, and the records report memory unchanged after every run.
The briefs
Briefs went to the agent word for word.
S1. Model a standard two-piece floor-mounted toilet against a back wall, with the wall and a side wall. Parent layer “Bath”. Inches.
S2. Make this an accessible single-user toilet room under the 2010 ADA Standards. The room is 60 in wide and 84 in deep. Add the grab bars.
S2 planted correction, sent after the agent’s first report: You missed the toilet paper dispenser. ADA 604.7: 7-9 in in front of the water closet, measured to the centerline of the dispenser, outlet 15-48 in above the floor.
S3. Turn this into a public restroom with two toilet compartments side by side along the back wall: one wheelchair-accessible compartment and one standard compartment, with partitions and doors, plus one accessible lavatory. Keep the existing toilet as the accessible one and adjust the room as needed.
From S2 on, each brief was one message: a line telling the agent to read the whole skill file with run_python and to resolve the skill’s relative links against its folder, then the brief. We built this line to stand in for a Rhino command (ASRhino) that would hand the agent the skill. The command was not built.
The tester gave scripted answers to the agent’s questions: floor-mounted; the left wall when facing the toilet; 1.5 in grab bar diameter; doors swing out of the compartments; “Confirmed.” to requirement tables; “Change the Bath model.”; “Only what the brief says.” for scope; “Yes, proceed.” to moving requirements to history; and “Use your judgment and say what you assumed.” for anything else.
The probe design
Planned November 7 after S3 could not test the lesson (see “Corrections and failures”). P1 and P2 each ran the S2 brief from the saved S1 model (a standard toilet, requirements revision 1), hooks off, with the skill line, scripted answers, and no planted correction. P1 used a copy of the skill and templates in which the ADA toilet variant included the 604.7 dispenser. P2 used a copy without it. The scope answer stayed “Only what the brief says.”
Skill, tools and configuration the runs loaded
| Item | What it was |
|---|---|
| Host | The Rhino 9 AI panel on macOS, which runs the Claude Agent SDK. Rhino 9.0.26300 was recorded on November 4; we did not re-record the build for later runs. |
| Agent model | Not recorded in the run files. The planning session in the same panel ran claude-opus-5-5, and the test plan’s cost estimate assumed Opus. We treat the model of the seven runs as unverified. |
| Client version | The planning session’s rows show Agent SDK client 2.1.316 until 16:06 on November 4, 2.1.318 until 11:26 on November 6 and 2.1.319 after that (times are Montevideo local, UTC−3). The run conversations’ own versions were not recorded. |
| Tools the model received | Per the S1 follow-up, the panel sent the Rhino MCP tools plus advisor (46 tools): no Skill, Read or Bash tool and no skill listing. A plugin skill cannot load in the panel. |
| User-level instructions | Loaded in every run: the operator’s user-level CLAUDE.md (1,728 bytes, unchanged since September 10). It holds four standing rules on outward messages, deploys, software installs and destructive actions. It has no modeling content. |
| Other plugin hooks | The panel loads plugin hooks, including SessionStart hooks. The planning session shows SessionStart hooks from other installed plugins failing with node: command not found. The operator had four plugins installed besides the test plugin. We did not isolate them. |
| Auto-memory | Panel project memory, snapshotted before each run (seven snapshots, no files); the records report it unchanged after every run. |
| Test plugin | as-rhino-test, built from the v7 branch: the rhino and rhino-setup skills, the requirements template and, for S1, two hooks. Installed from a local marketplace. Removed and the configuration restored after S3 and the probe (November 7). |
| S1 | Test plugin enabled with the requirements-first hook (PreToolUse) and the check gate (Stop). The skill was unreadable to the agent until the first denial named it. The SessionStart context hook that later put a skill core in context was built after S1. |
| S2a to P2 | Test plugin disabled: no hooks. The skill reached the agent only through the brief’s read-the-skill line. |
| Skill and template commits | S1 50f039a. S2a and S2 ran on the version after two hand edits to SKILL.md (see below). S3 (edf8c68) and P1 (54bebe4): the same plus the adopted dispenser lessons. S3 control and P2: 17acef7, the two hand edits and no lessons. |
The ASCheck command | A Rhino 9 plugin command that runs _-RunPythonScript on the checker. It printed only “Done.” in several runs (see “Corrections and failures”); the skill’s fallback, running the script through run_python, produced the status lines. |
The two hand edits between S1 and S2 were made by the maintainer, not by the learning step: the skill now names the Requirements: status line as the reply’s first line and keeps the machine ASCHECK line out of the reply, and it no longer calls template code values with a verified date unverified.
The checker and its requirements
as-check.py reads the requirements stored in the document (as:requirements) and runs as-check-model.py, the same measuring engine as our Rhino evaluations. The check types in these runs were: units, layer (object counts and types under the parent layer), named, valid, closed, extent (a child layer’s combined bounding box against [lo, hi] ranges on min, max, size or mid per axis) and clear (nothing inside a stated free volume). Requirements carry a brief, a sources map, a list of stated items that are recorded but not measured, and a revision. From revision 2 a change note is required. Writing goes through as-check.py’s write mode, which numbers the revision, moves the previous one to as:requirements-history and prints a ASREQUIREMENTS saved line. A check run ends with a line of the form ASCHECK status=pass checks=16/16 stated=6 rev=1.
The toilet template (toilet.json) holds a standard variant and an ADA variant in a local frame (centerline, back-wall face, floor), every entry sourced. Code entries carry the code section. ADA values were read against the 2010 ADA Standards text on November 4; IPC 2021 405.3.1 was read through its reproduction in IBC 2024 2903.1.1, because the ICC site refused automated reads. The template had no dispenser, by design, until the S2 correction was adopted.
The grader and the answer keys
Keys scenario-s1, scenario-s2 and scenario-s3 were written before each run, in each fixture’s own frame, from the code text above. The grader as-grade-scenario.py finds each fixture’s frame from geometry and from role words in layer and object names (toilet, tank, seat, grab, dispenser, wall, partition, door, lavatory), copies the model into a headless document with role layers, and runs the key through as-check-model.py. We checked it on stand-in models before S1: an ADA room rotated 90 degrees and moved off the origin passed S2’s key 22 of 22; three planted defects (dispenser 4 in forward, room 4 in short, no flush handle) failed exactly those checks; the S1 key failed a wrong seat height; an S3 layout passed all three frames and failed when the standard compartment’s dispenser was removed.
Claude, working with us in the planning session, wrote the keys, the grader, the skill and the checker. The tester ran the scenarios and gave the scripted answers.
Budget
The plan estimated $1 to $3 per scenario on Opus and $5 to $12 for three scenarios plus the S3 control, plus one maintainer session per learning step. We set no cap. Cost per panel run was not recorded.
Raw workflow
All times are Montevideo local (UTC−3).
November 4: the check command and the gate hook
ASCheck. The first version ran the evaluations’ checker unchanged on a requirements file stored in the document, added baseline checks, printed failures first with the measured value, the requirement and its source, and ended with the status line. On a test toilet with a 15-check requirements file, a clean model passed 15 of 15 through three routes: run_python, _-RunPythonScript, and the ASCheck command. Three planted defects were each caught: the seat raised 1 in failed the seat-height check, a lid name cleared failed named and the baseline named check, and an opened tank lid failed closed. After reverting, 15 of 15 again. A missing checker file was reported as a failure, not a pass.
Three findings changed the checker. Rhino corrects inside-out solids when they are added to the document, so the “solids positive volume” baseline check was redundant and we dropped it (14 checks). A run_python script that calls RhinoApp.RunScript loses its own printed output, so the agent runs the command through run_command. And a _-RunPythonScript run reads os.environ once when Rhino’s Python starts, so the first ASRequirements ran in check mode; the checker now reads its mode through System.Environment.
After the plugin library was rebuilt with the commands already loaded, both commands failed with TypeLoadException until Rhino restarted. We changed the design so the commands are created once and updates ship as script updates.
The gate. as-rhino-check-gate.py reads only the transcript and judges the current turn. A model change is a run_python or run_csharp call whose code (string literals and comments removed) calls a document-changing API, any run_command except ASCheck, Grasshopper canvas edits, and document operations. It allows the stop when there was no change, when a passing ASCHECK line follows the last change, when ask_user follows the last change, or on any hook error. Otherwise it blocks once. Its self-test went from 12 of 12 to 16 of 16 as we added cases.
We replayed it on the 18 turns of that morning’s panel session. It flagged one: “model me a toilet”, which changed the model with no check. The first version also flagged three turns that wrote files whose text mentioned RhinoCommon calls; ignoring string literals and comments fixed that.
Panel tests of the gate. In the first test (“Move the toilet seat up 1 inch”) the gate crashed and failed open. The panel’s Agent SDK process inherits Rhino’s PYTHONHOME, so /usr/bin/python3 (3.9) loaded Rhino’s 3.13 libraries and died at startup. Hooks that need node fail the same way. We ran hooks through a launcher that uses Rhino’s bundled Python with -I (isolated mode). In the second test (“Move the toilet seat back down 1 inch”) the gate blocked after the agent had written a “done” reply; the agent ran ASCheck (15 of 15 at that time) and the next stop was allowed. With no v7 skill loaded, the block message alone was enough for it to run the right command. The cost on a passing model was one extra run_command and one extra reply.
A third test confirmed that plugin hooks load in the panel. The agent edited through run_csharp, the gate detected it and blocked once, and the agent ran ASCheck (14 of 14) and finished. The screenshot showed three defects: the gate’s opening line was glued to the end of the previous paragraph, the final message repeated the first, and the agent said “a stop hook then asked for an ASCheck run”. We changed the block message (blank line first, no repeated summary, no mention of hooks) and added a rule to the skill that the agent runs ASCheck before replying so the gate rarely fires.
The rest of the build, the same day. We renamed the elements (Requirements, ASCheck, ASRequirements, as- prefixes, hyphens in file names, /as:rhino) and built the scenario prerequisites: the planner section of the skill (requirements first; sources; template order; confirm through ask_user when values come from a code, a reference image or a variant choice; revise before rebuilding; ASCheck before replying; the reply opens with the status line); the toilet template; requirement revisions in the format; the requirements-first hook (self-test 11 of 11), which denies the first model change until the transcript shows ASREQUIREMENTS saved or an ASCHECK line from this session; the test plugin and the configuration backup and restore; the memory snapshot tooling; the answer keys and the grader; and a harvester that reads a transcript and writes an inbox file of script errors, revisions, check results, user corrections and defaults. A dry run of the ADA template with a box stand-in passed 17 of 17 with 4 stated items; with the seat 1 in low and the side bar at 38 in, ASCheck failed exactly those two. It also found a template defect: the ADA tank limit silently overwrote the standard tank range on the same key. We fixed the merge rule.
November 4, 14:56 to 15:04: S1
We sent the S1 brief in a new panel conversation with the test plugin enabled. The agent’s first build script came before any requirements. The requirements-first hook denied it. The agent then read the skill’s Requirements section, wrote revision 1 (16 checks, 6 stated), showed the table, and asked for confirmation because IPC values were involved; the tester answered “Yes, build with these”. The agent built in three scripts and ran the check: pass, 16 of 16. In between it took about 8 viewport captures that came back blank, although the skill says to capture only when asked. Its reply opened with the machine line (ASCHECK status=pass ...) and said it had patched the bowl with Replace after the bowl-opening boolean returned an empty array, instead of rebuilding. The recorded sequence is x R1 w w w cp: one denial, requirements revision 1, three model changes, check pass.
Our grader returned 13 of 14. We found the failure was in our key (see “Corrections and failures”). The key fixed, it returned 16 of 16.
November 4, after S1: learning step and host findings
We ran the maintainer session for S1 headless (claude -p, Opus 5.5, in a separate git worktree, local commits only). It drafted no change: its table has six rows, and none recommends one. At the same time we looked into why the agent had not loaded the skill, and found the panel sends the model no Skill tool. We tried three delivery routes: a SessionStart hook that injects a skill core (the panel truncated the first 14 KB injection to a 2 KB preview, so we cut it to 2.9 KB); a stdlib MCP server registered in the panel’s AI Settings (this worked in the panel; plugin .mcp.json servers are ignored); and the live Arch Studio MCP server (it connected from the panel only after a login from terminal Claude Code, which we judged too complicated for Rhino users, and removed). We also recorded that with two skill channels the agent got conflicting first steps and two skill folders.
November 5 to 6: the on-demand decision
On November 5 we decided that always-on hooks, which would block every geometry change in every panel chat until requirements exist, were the wrong delivery, and that Arch Studio should be called on demand. On November 6 we changed the test plan to test that setup for S2 and S3 without building the command: the test plugin disabled, and the brief carrying the line ASRhino would print. We added two measures, M11 (whole skill read, before the first change) and M12 (check after the last change in each changing turn), and made the two hand edits to the skill described in “Inputs”.
November 6: S2a, S2 and the learning step
S2a (11:26 to 12:05 by file times) broke the script. The skill line and the brief arrived as two messages, and the tester gave three off-script answers (“Start a new model under a new parent layer”, “centerline at 18 in”, “Add an entry door and a wall-hung lavatory”). The agent built a new room on a Toilet Room layer beside Bath and never converted Bath, so the old model never failed against the new requirements. It wrote revision 2 (34 checks, 10 stated) and passed 34 of 34. The planted correction was not sent. We kept the run as a data point and reran S2 from the saved S1 model, after adding scripted answers for those three questions.
S2 (12:06 to 13:06 by file times). The agent read the whole skill, wrote revision 2 with a change note, and showed the table. The tester confirmed with “Yes, build to revision 2”, not the scripted seat-height reply, so that probe was lost. For the layout and scope questions the tester answered “whatever the plan says”. The agent put the toilet on the 84 in wall and read the scope answer as yes to a lavatory, an outswing door and grab bar mounts, which the brief did not ask for; it said so in its reply. It built the room in one generator script and its check returned 33 of 33 with 10 stated items. In its first report it said the back 1 in of the seat and lid ran into the tank front. No check measured that, and it left it.
We sent the planted correction. The agent wrote revision 3 first (dispenser centerline 7 to 9 in in front of the toilet’s front edge, outlet 15 to 48 in, top at least 1.5 in below the side bar’s underside, ADA 609.3) and then rebuilt everything on a cleared parent layer. The first rebuilt check failed: it had put the dispenser on a layer named “Toilet paper dispenser”, the toilet checks find their layers by the word “toilet”, so the dispenser counted as toilet and the toilet’s projection measured 41 in. The agent diagnosed that from the measured box, renamed the layer “Paper dispenser”, deleted the old layer, wrote revision 4 (which fixed a stated line that still said dispensers were not modeled), and rebuilt. Final check: pass, 36 of 36, 11 stated. The recorded sequence is R2 w cp R3 w cf R4 w cp.
Learning step. We ran the maintainer session headless on S2 (about 4 minutes, 40 turns, $1.61) with S1 reconsidered. It drafted two template changes and a ten-row table. The tester adopted both, with a maintainer amendment: the dispenser requirement in the ADA variant (centerline 7 to 9 in in front of the bowl, outlet 15 to 48 in high, top 1.5 in below the grab bar) and an exclude: ["dispenser"] on the Toilet layer check with a layer-name note. The maintainer then verified 604.7 against the code text and added “not behind grab bars”. On the question whether ASCheck should run on the unchanged model after a new revision, the session found it would have caught nothing the post-build check missed: in revision 2 the agent rebuilt everything anyway, in revision 3 it would have failed only the three dispenser checks that were missing by construction, and revision 4 changed only a stated line. We dropped “ASCheck fail between” from M7 on those grounds.
November 7: S3, the control, the probe and the write-up
S3 (the saved model is dated 17:39). The start file was S2’s final state (revision 4, 36 of 36). The agent read the whole skill and also the toilet template and elements.md. It asked six questions (code basis, door swings, lavatory location, entry door, room size, partitions), and the tester chose its recommended options. It wrote revision 5 before building, then found its own 126 in room depth too shallow: a 34 in outswing compartment door sweeps to 95 in, so the lavatory’s 48 in approach space needs the front wall at 144 in. It wrote 144 into revision 5 before building and flagged the change. It built partitions, doors, a standard toilet copied from the accessible one, and a lavatory, and ran the checker script directly because the ASCheck command printed only “Done.”. Result: 56 of 56 with 17 stated; sequence R5 w cp.
S3 control (17:41 to 17:53 by file times). Same start file, brief and environment, with the skill and templates at 17acef7. The agent asked 2 questions, built a 97 × 134 in room and passed 54 of 54 with 17 stated.
Probe (P1 17:57 to 18:14, P2 18:14 to 18:22 by file times). Both from the S1 model. P1 wrote revision 2 and its check returned 24 of 25: its 60 in turning circle failed against a room kept at 84 in deep (about 3.4 in of overlap with the bowl and seat), because the tester answered that the room stays 84 in. P2 had one failure (the grab bar layer held 10 objects against an allowed 2 to 8, because each flange and post were separate solids), unioned them, rebuilt and passed 24 of 24; sequence R2 w cf w cp.
Write-up. The tester stopped testing. We wrote the results into the spec and restored the configuration: uninstalled the test plugin and its marketplace with Claude Code’s commands, then restored settings.json, installed_plugins.json and known_marketplaces.json from the November 4 backup. Before restoring we checked that the only differences from the backup were the test plugin’s entries and one marketplace timestamp.
Metrics
Flow and cost, by run
Counts are from the harness’s metrics files for each run. “User messages” is the harness count and includes the brief.
| Run | Requirements first | Skill read whole | Turns with changes, checked after last change | User messages | Tool calls | Denials | Gate blocks | Sequence |
|---|---|---|---|---|---|---|---|---|
| S1 | yes | no (read the Requirements section after the denial) | 1 of 1 | 2 | 22 | 1 | 0 | x R1 w w w cp |
| S2a | yes | yes | 1 of 1 | 4 | 14 | 0 | 0 | R2 w w w cp |
| S2 | yes | yes | 2 of 2 | 3 | 15 | 0 | 0 | R2 w cp R3 w cf R4 w cp |
| S3 | yes | yes | 1 of 1 | 2 | 10 | 0 | 0 | R5 w cp |
| S3 control | yes | yes | 1 of 1 | 2 | 10 | 0 | 0 | R5 w cp |
| P1 | yes | yes | 1 of 1 | 2 | 9 | 0 | 0 | R2 w cf |
| P2 | yes | yes | 1 of 1 | 2 | 14 | 0 | 0 | R2 w cf w cp |
In the sequence notation, R<n> is a requirements revision, w a model change, cp a check that passed, cf a check that failed and x a denied change. Across the seven runs the range is 9 to 22 tool calls, 592,304 to 1,101,072 input tokens (the test plan describes these as mostly cache reads; we did not recompute the split) and 18,021 to 42,592 output tokens. The spec’s summary gives the output range as “20 to 43k”; the smallest recorded value is S1’s 18,021.
Time was not measured. File timestamps bracket the run between the memory snapshot and the saved model, and include the tester’s answers and scoring steps: S1 8 minutes, S2a 39, S2 60, S3 control 12, P1 17, P2 8. S3’s snapshot was taken the day before the run, so we have no bound for it.
Learning-step sessions
| Session | Model | Cost | Turns | Duration | Drafted |
|---|---|---|---|---|---|
| S1 | claude-opus-5-5 | $1.01 | 26 | 121 s | Table of 6 rows; no template or skill change |
| S2 (with S1 reconsidered) | claude-opus-5-5 | $1.61 | 40 | 254 s | 2 template changes, table of 10 rows |
Total $2.63. No learning session had been run for S3 by November 7; an inbox file was written for it.
Independent grading, by run
| Run | Key as written | After key fix | Review items |
|---|---|---|---|
| S1 | 13 of 14 (failed: extent toilet, max_z 35.12 in) | 16 of 16 | 0 |
| S2 | 21 of 22 (failed: clear barrier, a free-volume line at x = 12 in blocked) | 23 of 23 | 1 |
| S3, accessible frame | 22 of 22 | n/a | 0 |
| S3, standard frame | 8 of 8 | n/a | 1 (no dispenser in the standard compartment) |
| S3, lavatory frame | 6 of 6 | n/a | 0 |
| S3 control | same as S3 | n/a | same as S3 |
| P1 | 21 of 22 (failed: found dispenser) | n/a | 3 |
| P2 | 21 of 22 (failed: found dispenser) | n/a | 4 |
In S1, S2 (after the key fix), S3 and the S3 control, the agent’s check and the independent grade both passed. In P2 the agent’s check passed 24 of 24 while the key failed 21 of 22 (the plan calls this an M6 gap: the agent’s check passes and the independent check fails). In P1 the two failed on different items: the agent’s one failure, the turning circle, is not a key item, and the key’s failure, the dispenser, is not on the agent’s list.
What each run produced
| Run | Objects | Notes |
|---|---|---|
| S1 | 11 | Standard toilet (bowl, seat, lid, tank, flush) with a back wall and a side wall, 4.5 in thick and 96 in high. Seat top 15.875 in, bowl front 29.75 in from the wall, side wall face at x = −15 in, width 21 in, tank lid top 30 in |
| S2a | 25 | An accessible room on a new layer beside Bath, passing 34 of 34; not scored |
| S2 | 26 | Accessible room 60 × 84 in, toilet centerline 18 in from the side wall, seat top 17.5 in, side bar 42 in long and rear bar 36 in long at 34.5 in, 1.5 in off the wall, lavatory, outswing door, dispenser at y = 38 in, outlet 24 in above the floor |
| S3 | 39 | Restroom 97 × 144 in, accessible compartment 60 × 60 in, standard compartment 36 in wide, partitions, doors, lavatory |
| S3 control | 42 | Restroom 97 × 134 in, door swings not modeled |
| P1 | 19 | 60 × 84 in room, side bar 43 in long, rear bar 37 in long; no dispenser |
| P2 | 20 | 60 × 84 in room, side bar 48 in, rear bar 42 in; no dispenser |
The S2 requirements, as an example of what a requirements revision held
Revision 2, from the first reply in S2 (positions measured from the finished floor, the toilet centerline and the face of the back wall):
| Requirement | Value | Source |
|---|---|---|
| Room | 60 × 84 in finished interior | brief |
| Toilet centerline from side wall | 18 in (allowed 16 to 18) | tester; ADA 604.2 |
| Toilet clearance | 60 × 56 in, no walls, lavatory or door in it | ADA 604.3.1, 604.3.2 |
| Seat height | 17 to 19 in | ADA 604.4 |
| Side grab bar | 42 in min, starts at most 12 in from the back wall, reaches at least 54 in | ADA 604.5.1 |
| Rear grab bar | 36 in min, at least 12 in toward the side wall and 24 in toward the open side | ADA 604.5.2 |
| Grab bar height and wall gap | top 33 to 36 in; 1.5 in | ADA 609.4; 609.3 |
| Flush control | open side, 15 to 48 in | ADA 604.6, 309.3 |
The agent marked its own additions (lavatory, door, turning space, ADA 304, 305, 306, 404, 606) as working values still to be checked against the code text.
The lesson probe
| P1 (lesson) | P2 (control) | |
|---|---|---|
| Dispenser in the requirements or the model | no | no |
| Dispenser raised by the agent | yes: offered “Toilet paper dispenser (ADA 604.7)” as an optional addition beside a door and a lavatory; its stated line lists the dispenser as out of this revision’s scope | no: never mentioned (the word appears only in the checker’s help text it read) |
Layer-name exclude applied | yes: the Toilet layer check carries exclude: ["dispenser"] | n/a |
| Self-check | 24 of 25 (turning circle unmet, accepted by the tester) | 24 of 24 after one fix |
| Independent (S2 key) | 21 of 22; the fail is the missing dispenser | 21 of 22; same fail |
| Tool calls, input and output tokens | 9; 592,304; 21,218 | 14; 753,674; 23,357 |
S3 and its control
| S3 (lessons) | Control (no lessons) | |
|---|---|---|
| Questions asked | 6 | 2 |
| Self-check | 56 of 56, 17 stated | 54 of 54, 17 stated |
| Independent | 22 of 22, 8 of 8 (+1 review), 6 of 6 | 22 of 22, 8 of 8 (+1 review), 6 of 6 |
| Corrections, repeated errors | 0, 0 | 0, 0 |
| Tool calls, input and output tokens | 10; 739,873; 39,398 | 10; 817,526; 36,872 |
| Room | 97 × 144 in; agent deepened it after finding its 126 in proposal too shallow | 97 × 134 in; door swings not modeled, cleared from layout numbers |
| Standard toilet | copy of the accessible toilet, bowl lowered to a 15.75 in seat | copy translated, seat 17.5 in, outside its own 15 to 16 in default (stated) |
| Seat and lid into the tank | in both toilets | in both toilets |
Outputs
The seven models are saved Rhino files with their requirements, requirement history, check results, grades and metrics, kept in our internal test records. They are not public. We opened none of the model files for this article; the figures above come from the grader’s text output, the exported requirements and the agent’s own replies as we pasted them. No image from these runs exists that we could verify: from S2 on the agent took no captures (“Capture: none; geometry checks only”), and S1’s captures were blank views. We therefore propose no figures.
The internal records behind this article are: the v7 spec (section 11, written November 7), the scenario test plan with its results (section 10), the toilet requirements template and its adopted changes, and the learning-step inbox and drafts files.
Corrections and failures
S1 key defect. The key capped the whole Toilet layer’s height at 33 in, which a raised seat lid exceeds (35.12 in measured). We changed it to measure the tank, and added a grader role for a tank lid, which raised the tank layer count from 1 to 2. S1 went from 13 of 14 to 16 of 16. We also fixed the harvester’s token counting (message ids). The agent’s result did not change.
S2 key defect. The room-size checks assumed the toilet on the 60 in wall; the brief did not fix the orientation and the agent put it on the 84 in wall. We added an either check that accepts both orientations. S2 went from 21 of 22 to 23 of 23. One review item remains, “either room walls enclose the 60 × 84 in interior”: both orientations fail inside walls, because the end wall is named “End wall with door opening” and the grader classes it as a door. It is a grader limit, not a model defect. Both key defects were found after seeing the results, and we fixed them after, not before. In both, the agent’s design was valid and the key assumed one design.
S2a voided. Two messages instead of one and three off-script answers produced a different task. We did not score it as S2.
S2 deviations. The seat-height confirmation probe was lost (the tester sent “Yes, build to revision 2”), and the “whatever the plan says” answer let the agent add a lavatory, a door and mounts beyond the brief.
S2 ASCheck before rebuild not required. M7 as first written in the plan included “ASCheck failed between the revision and the rebuild”. S2 did not do that step and the skill does not ask for it. We dropped it from M7 on November 6 after the learning session; M7 now reads: revision before model edit, pass after, no stale values. The harness records the first and last of those as true in all six hooks-off runs; it does not check for stale values.
S1 enforcement versus the rest. S1 ran with hooks and S2 onward without. Its M1, M7 and M12 are not like for like with the others. The test plan’s note under S1 says “From S2 on, a SessionStart hook puts a skill core in context”; the later decision of November 6 turned all hooks off. We follow the later record.
S3 could not test the lesson. The S2 model, which was S3’s start file, already held the dispenser in its geometry and its revision 4 requirements. Both S3 and its control therefore started with the lesson’s content present. We recorded this limitation before running S3 and ran it anyway. The two runs are indistinguishable on every measure the lessons could affect. The plan’s O3 criterion (“L1 shows up in S3 and is absent from the control”) is not met, and we report O3 as not shown by S3.
The probe’s result. In P1 the lesson reached the agent as knowledge (it named 604.7) but not as a requirement: it filed the template’s dispenser under optional scope, and the scope answer removed it. The criterion for L1, a dispenser present unprompted, is not met. We proposed that the skill state that a variant’s entries are part of the element, or that the template mark entries as required with the variant. We did not rerun P1 with that change.
ASCheck printed only “Done.” In S3 the command printed only “Done.” in the panel. The maintainer confirmed that -RunPythonScript produces no output in this Rhino session and that the command history shows TLS exceptions from Rhino’s script connection. The skill’s fallback worked. The agent reported the same in the S3 control, P1 and P2; we did not check S2’s reply for it. A Rhino restart was expected to clear it and we did not test that. Our own check of S3 went wrong once: we ran the checker script without telling it where its checker file was and got status=fail checks=3/4 against the agent’s 56 of 56; the rerun, with the location given, matched the agent.
Defects in the S3 run, found by reading the transcript. The agent changed a value the tester had confirmed (room depth 126 to 144 in) without asking again, under the brief’s “adjust the room as needed”; it wrote the change into the requirements first and flagged it. It did a partial rebuild (walls, lavatory and entry door deleted and rebuilt, the standard toilet copied from the accessible one, the old faucet rotated onto the new lavatory), not a cleared parent layer as the skill asks. A source note overstated verification (“604.8.1.1 checked via template 604.3”); the agent caught this in its own reply and said it would correct it in the next revision.
The seat and lid overlap, never caught. In S2 the agent reported the back 1 in of the seat and lid running into the tank front. The maintainer measured about 9 cubic inches of overlap in each toilet in S3, and it was copied into the standard toilet; the control shows the overlap in both toilets too. No check measures it, and the S3 agent did not mention it. The S2 learning session had marked it “unconfirmed, seen once” and said that if it repeated it would draft a check. The spec of November 7 lists a part-overlap check as not built.
Where our records disagree with the data. (1) The spec’s conclusion 1 says the independent grader agreed with ASCheck in every run once the two key defects were fixed. The P2 grade (agent 24 of 24, key 21 of 22) and the P1 grade show it did not; the plan’s own rule is to report any such gap as a finding, and we do here. (2) The spec’s cost summary gives output tokens as “20 to 43k”; the smallest recorded value is S1’s 18,021. (3) The test plan’s S1 note says a SessionStart hook supplies the skill from S2 on; its later decision and the S2 metrics say hooks were off.
What later work reversed. The November 10 plan for the next open-source Arch Studio release, as recorded in our timeline draft, takes the ASCheck and ASRequirements Rhino commands and the two enforcement hooks out of scope, and states that the ASRhino loader command is not planned either. The checker script stays and is run by file path through run_python. The same record notes that ASCheck again printed only “Done.” in a November 9 session. This article’s results about the hooks and the command are therefore about a design that was not carried forward.
Lessons learned
Each lesson is tied to what happened and states its limit.
- Without enforcement, the plan, build and check order held in these runs when the brief told the agent to read the skill. In the 6 hooks-off runs the whole skill was read before the first change (M11), requirements came before the first build (M1), revision came before the model edit on a changed brief (M7), and the check ran after the last change in 7 of 7 changing turns (M12). Limit: the brief forced the skill read. In S1, where the skill was unreadable, the agent built first and the hook denied it once.
- The gate never fired in a scenario. Gate blocks were 0 in all seven runs. In S1 the agent checked before replying. The gate’s two recorded blocks were in panel tests on November 4, on seat-move turns that had no check, with no skill loaded. The scenario data cannot say what the gate adds when the skill is followed.
- A check covers its own list. In S2 (before the correction), P1 and P2 the requirements and the model had no dispenser. In P2 the agent’s check passed 24 of 24; in P1 and P2 the independent key failed 21 of 22 on exactly that item. The completeness of the requirements was the open risk, not the geometry measured against them.
- Answer keys that encode one design produce false failures. Two of the three graded scenarios (S1, S2) first showed a failure that was a key defect, and both keys were fixed after the result. Write the key as ranges and
eitheroptions before the run. - Layer-name matching clashed with an added element, and the printed measured value made the cause findable in one step. “Toilet paper dispenser” counted as toilet and the check showed a 41 in projection; the agent renamed the layer and rebuilt. The adopted fix was an
excludeon the Toilet layer check and a note about role words in layer names. - A check only catches what it measures. The seat and lid overlap (about 9 cu in) passed every check in S2, S3 and the S3 control, in each toilet. A part-overlap check for the toilet was named as the next step and not built.
- A lesson test needs a start state that does not already contain the lesson. S3 and its control are indistinguishable on every measure the lessons could affect because the start file carried the dispenser. The probe used a start file without it.
- A template entry can be read as optional scope. With the strict scope answer “Only what the brief says”, the agent in P1 offered the template’s dispenser as an addition and left it out. The next change to try is to state, in the skill or the template, that a variant’s entries belong to the element. We did not test it.
- The learner saw only what the harvester collected. It saw script errors, check results and corrections. It did not see S1’s reply-line and screenshot defects, the patched bowl, or S2’s scope growth. Those came from reading the replies. Two were fixed by hand before S2.
- The panel is a different host from a terminal. It sends no
Skilltool, truncates large hook context to a preview, ignores plugin.mcp.jsonservers, and passes Rhino’sPYTHONHOMEto hook processes, which crashed our first gate until we ran hooks with isolated Python. Any hook, skill or command that works in terminal Claude Code needs its own test in the panel. - When the Rhino command printed nothing, running the same script through
run_pythonworked. The skill’s fallback produced the status line in S3, its control and P1 (and P2’s reply shows the same fallback). The command was the only part that failed.
Limits
- Run counts. One run per setup, seven runs in all (one of them off-script), all on one bathroom model. We have no estimate of run-to-run variation. The differences between S3 and its control (questions asked, room depth, standard seat height) are within what one trial cannot separate.
- No baseline without the skill. We did not run the same briefs with no skill or no requirements. The spec planned that comparison; it was not run. These runs show the agent following the process, not that the skill improves results.
- The grader and the keys are ours. Claude wrote the keys, the grader, the skill and the checker in one planning session, and revised two keys after seeing results. No architect reviewed the keys or the models. The ADA values were checked against the published text; IPC 405.3.1 through a reproduction.
- Coverage not computed. M2 (share of key requirements present in the agent’s list) and M3 (share of the agent’s values inside the key’s ranges) were scored by hand for S1 only. We have not computed them for the other runs.
- One operator, one machine, one Rhino build. The agent model for the runs was not recorded; we believe it was Opus 5.5 and have not verified it. Configuration was not isolated: the user-level instructions file, other plugins’ hooks and the panel’s defaults were all loaded.
- Not measured. Cost in dollars and wall time per panel run. The input-token split between cache reads and fresh input.
- Not tested. Sonnet or any other model; the on-demand command we designed for (
ASRhino); hooks in S2 and later; Windows; building types other than a bathroom; geometry other than boxes and extrusions; models reviewed visually; a rerun of P1 after the proposed wording change; an independent human reviewer. - The gate and the command. The gate was exercised in panel tests on November 4 and in S1 only; it blocked twice in the panel tests and 0 times in the scenarios. The
ASCheckcommand ran, but its output was empty in the panel for the later runs, and the later plan does not carry it forward.