Padron 444, San Carlos

Area

5.201 m²

Zone

1.4.2

Locality

San Carlos

Manzana

34

Padron 444 — 3D Envelope Open fullscreen →

Applicable Zone

Zona 1.4 — Subzona 1.4.2 (Resto)

Padron 444, Manzana 34, is within the San Carlos subdivision. It does not front Ruta 10 (ruling out Subzonas 1.4.1 Costanera Norte and 1.4.3 Costanera Sur). Subzona 1.4.2 (Resto) applies, covering all remaining properties in Zona 1.4.

Permitted Building Types

TypeMin. RequirementAvailable?
Detached unitYes
Semi-detached unitsYes
Unit cluster1,000 m² per unit, 6 m separationYes (up to 5 units)
Low blockNot permitted in Subzona 1.4.2No
Low-rise buildingNot permitted in Subzona 1.4.2No

With 5,201 m² and a minimum of 1,000 m² per dwelling, the lot supports up to 5 detached units with 6 m separation between them.

Building Envelope

Height

ParameterValue
Max height7 m
FloorsPB + PA (2 levels)
NotesNo galibo in this subzone

Occupation Factors

For lots over 1,000 m² (no interpolation required — minimum values apply):

Factor%
FOS SS25%1,300
FOS25%1,300
FOS V50%2,601
FOT50%2,601
FOS Garage (bonus)+10%+520 (does not count toward FOT)

Total FOS with garage bonus: 35% = 1,820 m² at ground floor.

Setbacks

DirectionDistanceNotes
Front6 mNot on Ruta 10
Lateral 13 m
Lateral 22 m
Rear3 m

Frontage ~68 m > 15 m — small-lot provisions do not apply.

Auxiliary Constructions in Setbacks

  • Storage, garages, covered barbecue areas, service rooms and bathrooms
  • Max 36 m², max average height 3 m
  • Location: from the midpoint of the lot toward the rear

Overhangs

2 m projection over front and rear setbacks, covering up to 30% of the facade surface.

Rooftop Services (Decreto 3876)

  • Barbecue area, bathroom, kitchenette: up to 20% of the roof surface
  • Max interior height: 2.60 m
  • Does not count as an additional level

Basement

  • Garages and services in the basement do not count toward FOT
  • FOS SS = 25% = 1,300 m² (same as FOS)

Development Potential

ScenarioUnitsFOS (m²)FOT (m²)Height
Single detached unit11,3002,6017 m
Semi-detached (2 units)21,3002,6017 m
Unit cluster (5 units)51,3002,6017 m
With garage bonus1,820 (PB)2,6017 m

FOT does not vary between scenarios (fixed at 50% for lots over 1,000 m²). The difference lies in distribution: a single large dwelling vs. up to 5 units of approximately 520 m² each.

Key Constraints

  • Height limited to 7 m — no possibility of low blocks or low-rise buildings in Subzona 1.4.2
  • Irregular lot shape — the L-form reduces implantation efficiency compared to an equivalent rectangular lot
  • 6 m separation between units in the cluster scenario — consumes significant usable area with 5 units
  • PH regime already established — allows subdivision into horizontal property units without additional subdivision procedures
  • Garage bonus (+10% FOS) — allows a larger ground floor footprint without impacting FOT
  • Basement free of FOT — underground garages and services do not count, up to 1,300 m² footprint