Padron 9083, Punta del Este

Area

1.303 m²

Zone

1.1.2

Locality

Punta del Este

Manzana

66

Applicable Zone

Zona 1.1 Faro — Subzona 1.1.2 Residencial

Source: TONE — Titulo II, Capitulo II, Sector 1, Art. D.183 (Dto.Jta.Dep. 3718/1997, Art. 181).

Use Restrictions

  • Single-family residential only — one dwelling per lot
  • Not permitted: hotels, apartments, offices, or commercial premises
  • Gastronomic exception only on specific streets (Rambla Portuaria, calles 8-14)

Building Envelope

Height

ParameterValue
Max height7 m (measured from recta de comparacion)
FloorsPB + PA (2 levels max)
IncludesMechanical room, water tank — everything within the 7 m

Occupation Factors

Factor%
FOS SS50%652
FOS50%652
FOT100%1,303
FOS Verde30%391

Setbacks

DirectionDistanceNotes
Front4 m6 m if fronting the Costanera
Lateral 12 m
Lateral 22 m
Rear2 m

Provision for lots with frontage < 12 m: one lateral setback may be occupied up to 3.50 m height — does not apply here (frontage is approximately 34 m).

Overhangs

  • 1.50 m projection over front setback
  • Along the full extent of the built volume
  • Minimum clearance: 2.40 m

Parking

1 space per dwelling (Art. D.180).

Mandatory Landscaping

Front setback must be landscaped.

Special Overlays and Restrictions

No special overlays apply to this lot:

RestrictionApplies?Reason
Art. D.170 — Special setbacks (coasts, routes)NoOnly for lots outside urban/suburban zones
Art. D.172 — Watercourse easement (150 m)NoExempt as consolidated urban core
Coastal defense strip (Water Code)NoFor new subdivisions, not existing urban lots
Heritage designationNoNo designation identified for Manzana 66
SNAP protected areasNoThe Punta del Este peninsula is not in a protected area

Historical Context — Non-Conforming Use

The property is currently marketed as a 2-story office or commercial premises, a use prohibited under the current 1997 code (single-family residential only). This is consistent with a legal non-conforming use (pre-existing) under the prior regulatory regime.

Prior Code: Decreto 3289/1974 (General Construction Ordinance)

The 1997 TONE replaced the 1974 General Construction Ordinance (Decreto 3289). Under the prior code:

  • The peninsula was a single zone — the Faro/Centro/La Pastora division did not exist
  • No use restrictions by zone — commercial, office, hotel, and residential uses were permitted throughout the peninsula
  • Height and towers were regulated by lot size and location (Gorlero + parallel streets), not use type
  • The “single-family only” restriction for the Faro tip was introduced in 1997 by Art. D.183

Implications for This Property

FactorAssessment
Current useOffice/commercial premises (2 stories)
Current zoningSingle-family residential only (1997)
Legal statusNon-conforming use — pre-existing before the 1997 code
Continue current useLikely permitted
Expand commercial useLikely restricted
Rebuild if destroyedMay not be permitted as commercial
Change commercial typeMay require review

Buyer caution: Verify non-conforming use provisions with the Intendencia de Maldonado before purchase.

Key Constraints

  • Single-family residential only — the primary restriction of this subzone
  • 7 m / 2 levels — low profile, consistent with the Faro neighborhood
  • FOS 50% is generous — up to 652 m² footprint
  • FOT 100% limits total built area to 1,303 m² across both floors
  • With 2 floors at 652 m² each, FOT is reached exactly — FOS and FOT are perfectly aligned
  • FOS Verde 30% requires at least 391 m² of green area — achievable with setbacks and garden
  • Irregular L-shape complicates design but with 1,303 m² there is ample room for a generous residence
  • Height includes everything — mechanical room, water tank must fit within 7 m